 ====== Facilities ====== ====== Facilities ======
  
-=====Media supply system=====+===== Media Supply System =====
  
 ==== Gases ==== ==== Gases ====
Line 12: Line 12:
  * Nitrogen 4.8  * Nitrogen 4.8
  * Oxygen 5.0  * Oxygen 5.0
- * Hydrogen 5.0 only in certain locations+ * Hydrogen 5.0 (only in certain locations)
  
 More information can be found in [[mchequip:mediasupply|Media Supply System]]. More information can be found in [[mchequip:mediasupply|Media Supply System]].
-==== Pressurized air ====+ 
 +==== Pressurized Air ====
  
 The pressurized air system is available at a maximum pressure of 8 bar. The air quality is standard technical air, it may contain oil residues and humidity to a certain extend. The pressurized air system is available at a maximum pressure of 8 bar. The air quality is standard technical air, it may contain oil residues and humidity to a certain extend.
Line 26: Line 27:
  
  
-=====Air ventilation system=====+===== Air Ventilation System =====
  
 The MCh building is locally equipped with an air ventilation system located on the roof installation center. The MCh building is locally equipped with an air ventilation system located on the roof installation center.
  
-<note tip>+<WRAP center round info 70%>
 The air ventilation system is not an air conditioning system! The air ventilation system is not an air conditioning system!
-</note>+</WRAP>
  
 This system provides fresh air in the lab floor, and in the office floors, but not in the offices. This system provides fresh air in the lab floor, and in the office floors, but not in the offices.
Line 40: Line 41:
 </note> </note>
  
-===Maintenance schedules===+==== Maintenance schedules ====
  
 The schedules are given out by RWTH central administration, Facility Management. The schedules are given out by RWTH central administration, Facility Management.
Line 47: Line 48:
   * KW: Kleine Wartung, Small Maintenance, 3h duration.   * KW: Kleine Wartung, Small Maintenance, 3h duration.
  
-===2016===+=== 2016 ===
  
-^Sub-system^Dates/extension^^^^+^Sub-System ^Dates/Extension ^^^^
 |Abluft, L.11, Graphitstaub, EG 3| |MW 28.04.2016| | |  |Abluft, L.11, Graphitstaub, EG 3| |MW 28.04.2016| | |
 |Zu- und Abluft, L.01, Labore, 3.OG|GW 28.01.2016|KW 28.04.2016|MW 28.07.2016|KW 27.10.2016| |Zu- und Abluft, L.01, Labore, 3.OG|GW 28.01.2016|KW 28.04.2016|MW 28.07.2016|KW 27.10.2016|
Line 60: Line 61:
  
  
-====Air cooling/air conditioning====+==== Air Cooling/Air Conditioning ====
  
 The seminar room and the meeting room are further equipped with a local air cooling system which cools down the standard ambient air supply in order to avoid people to get tired in meetings. The seminar room and the meeting room are further equipped with a local air cooling system which cools down the standard ambient air supply in order to avoid people to get tired in meetings.